Increase the setting value in steps of 5% if the motor stalls during run at constant speed.
■
n8-49: Heavy Load Id Current
No.
(Hex.)
Name
Description
Default
(Range)
n8-49
(053C)
RUN
Expert
Heavy Load Id Current
Sets the d-axis current to that the drive will supply to the motor to run it at a constant speed with a
heavy load. Considers
E5-03 [PM Motor Rated Current (FLA)]
to be 100%. Usually it is not
necessary to change this setting.
Determined by E5-01
(-200.0 - +200.0%)
When you use an IPM motor, you can use the reluctance torque of the motor to make the motor more efficient and
help conserve energy.
When you operate an SPN motor, set this parameter to 0.
Adjust in the following situations.
•
If the load is large and motor rotation is not stable, decrease the setting value.
•
When you change the
E5 parameters [PM Motor Settings]
, set
n8-49 = 0
, then adjust this parameter.
■
n8-50: Medium Load Iq Level (High)
No.
(Hex.)
Name
Description
Default
(Range)
n8-50
(053D)
Expert
Medium Load Iq Level
(High)
Sets the load current level at which heavy load control starts where
E5-03 [Motor Rated Current
(FLA)]
is 100%. Usually it is not necessary to change this setting.
80%
(50 - 255)
■
n8-51: Pull-in Current @ Acceleration
No.
(Hex.)
Name
Description
Default
(Range)
n8-51
(053E)
Pull-in Current @
Acceleration
Sets the pull-in current allowed to flow during acceleration/deceleration as a percentage of the
motor rated current.
Determined by A1-02
(0 - 200%)
Adjust in the following situations.
•
When the motor does not smoothly because of large loads, increase the setting value in 5% increments.
•
If too much current flows during acceleration, decrease the setting value.
Note:
When
A1-02 = 8 [Control Method Selection = EZOLV]
, this parameter will always be in effect for speed ranges less than
n7-10 [Pull-in
Current Switching Speed]
.
■
n8-54: Voltage Error Compensation Time
No.
(Hex.)
Name
Description
Default
(Range)
n8-54
(056D)
Expert
Voltage Error
Compensation Time
Sets the time constant that the drive uses when adjusting for voltage errors.
1.00 s
(0.00 - 10.00 s)
Adjust this parameter in these conditions:
•
If oscillation occurs at the time of start up, increase the setting value.
•
If hunting occurs when operating at low speed, increase the setting value.
•
If fast changes in the load cause hunting, increase the setting value in 0.1-unit increments. If you cannot stop
hunting, set
n8-51 [Pull-in Current @ Acceleration]
to 0% and set
n8-54
to 0.00 s, and disable compensation
for voltage errors.
■
n8-55: Motor to Load Inertia Ratio
No.
(Hex.)
Name
Description
Default
(Range)
n8-55
(056E)
Motor to Load Inertia Ratio
Sets the ratio between motor inertia and machine inertia.
0
(0 - 3)
Adjust in the following situations.
•
If torque and speed response is unsatisfactory, gradually increase the setting from 0.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...