11.13 o: Keypad-Related Settings
YASKAWA
SIEPC71061753A GA500 Technical Manual
403
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
o1-41
(11C1)
RUN
1st Monitor Area
Selection
Sets the horizontal range used to display the monitor set in
o1-24 [Custom Monitor 1]
as a bar graph. This parameter is only available when using an LCD keypad.
0 : +/- Area ( - o1-42 ~ o1-42 )
1 : + Area ( 0 ~ o1-42 )
2 : - Area ( - o1-42 ~ 0 )
0
(0 - 2)
o1-42
(11C2)
RUN
1st Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in
o1-24 [Custom Monitor
1]
as a bar graph. This parameter is only available when using an LCD keypad.
100.0%
(0.0 - 100.0%)
o1-43
(11C3)
RUN
2nd Monitor Area
Selection
Selects the horizontal range used to display the monitor set in
o1-25 [Custom Monitor
2]
as a bar graph. This parameter is only available when using an LCD keypad.
0 : +/- Area ( - o1-44 ~ o1-44 )
1 : + Area ( 0 ~ o1-44 )
2 : - Area ( - o1-44 ~ 0 )
0
(0 - 2)
o1-44
(11C4)
RUN
2nd Monitor Area
Setting
Sets the horizontal axis value used to display the monitor set in
o1-25 [Custom Monitor
2]
as a bar graph. This parameter is only available when using an LCD keypad.
100.0%
(0.0 - 100.0%)
o1-45
(11C5)
RUN
3rd Monitor Area
Selection
Sets the horizontal range used to display the monitor set in
o1-26 [Custom Monitor 3]
as a bar graph. This parameter is only available when using an LCD keypad.
0 : +/- Area ( - o1-46 ~ o1-46 )
1 : + Area ( 0 ~ o1-46 )
2 : - Area ( - o1-46 ~ 0 )
0
(0 - 2)
o1-46
(11C6)
RUN
3rd Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in
o1-26 [Custom Monitor
3]
as a bar graph. This parameter is only available when using an LCD keypad.
100.0%
(0.0 - 100.0%)
o1-47
(11C7)
RUN
Trend Plot 1 Scale
Minimum Value
Sets the horizontal axis minimum value used to display the monitor set in
o1-24
[Custom Monitor 1]
as a trend plot. This parameter is only available when using an
LCD keypad.
-100.0%
(-300.0 - +300.0%)
o1-48
(11C8)
RUN
Trend Plot 1 Scale
Maximum Value
Sets the horizontal axis maximum value used to display the monitor set in
o1-24
[Custom Monitor 1]
as a trend plot. This parameter is only available when using an
LCD keypad.
100.0%
(-300.0 - +300.0%)
o1-49
(11C9)
RUN
Trend Plot 2 Scale
Minimum Value
Sets the horizontal axis minimum value used to display the monitor set in
o1-25
[Custom Monitor 2]
as a trend plot. This parameter is only available when using an
LCD keypad.
-100.0%
(-300.0 - +300.0%)
o1-50
(11CA)
RUN
Trend Plot 2 Scale
Maximum Value
Sets the horizontal axis maximum value used to display the monitor set in
o1-25
[Custom Monitor 2]
as a trend plot. This parameter is only available when using an
LCD keypad.
100.0%
(-300.0 - +300.0%)
o1-51
(11CB)
RUN
Trend Plot Time Scale
Setting
Sets the time scale (horizontal axis) to display the trend plot. When you change this
setting, the drive automatically adjusts the data sampling time. This parameter is only
available when using an LCD keypad.
300 s
(1 - 3600 s)
o1-55
(11EE)
RUN
Analog Gauge Area
Selection
Sets the range used to display the monitor set in
o1-24 [Custom Monitor 1]
as an analog
gauge. This parameter is only available when using an LCD keypad.
0 : +/- Area ( - o1-56 ~ o1-56 )
1 : + Area ( 0 ~ o1-56 )
1
(0, 1)
o1-56
(11EF)
RUN
Analog Gauge Area
Setting
Sets the value used to display the monitor set in
o1-24 [Custom Monitor 1]
as an analog
meter. This parameter is only available when using an LCD keypad.
100.0%
(0.0 - 100.0%)
o1-58
(3125)
Motor Power Unit
Selection
Sets the setting unit for parameters that set the motor rated power.
0 : kW
1 : HP
0
(0, 1)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...