524
YASKAWA
SIEPC71061753A GA500 Technical Manual
When output frequency get
C1-11
value, the drive automatically switches the acceleration and deceleration times.
Set this parameter to
0.0
to disable this function.
Figure 12.37 Accel/Decel Time Switching Frequency
lists the possible combinations of acceleration and deceleration time switchover frequencies and the
acceleration times for the Motor 2 Selection function.
Table 12.37 Motor and Acceleration and Deceleration Time Combination
C1-11
Motor 1
Motor 2
Acceleration Time
Deceleration Time
Acceleration Time
Deceleration Time
Less than the setting value
C1-07 [Acceleration Time 4]
C1-08 [Deceleration Time 4]
C1-07 [Acceleration Time 4]
C1-08 [Deceleration Time 4]
Equal to or more than the setting
value
C1-01 [Acceleration Time 1]
C1-02 [Deceleration Time 1]
C1-05 [Acceleration Time 3]
C1-06 [Deceleration Time 3]
■
C1-14: Accel/Decel Rate Frequency
No.
(Hex.)
Name
Description
Default
(Range)
C1-14
(0264)
RUN
Accel/Decel Rate
Frequency
Sets the base frequency used to calculate acceleration and deceleration rates.
0.0 Hz
(0.0 - 590.0 Hz)
The acceleration and deceleration rates set in
C1-01 to C1-09 [Acceleration/Deceleration Times 1 to 4, Fast Stop
Time]
will change when the value of
C1-14
changes.
•
When
C1-14 = 0.0 Hz
–
C1-01, C1-03, C1-05, C1-07 [Acceleration Times 1 to 4]:
Time to accelerate from 0 Hz to
E1-04 [Maximum
Output Frequency]
–
C1-02, C1-04, C1-06, C1-08 [Deceleration Times 1 to 4], C1-09 [Fast Stop Time]:
Time to decelerate from
E1-04
to 0 Hz.
Figure 12.38 Example 1: Acceleration/Deceleration Rate (When C1-14 = 0 Hz, E1-04 = 60 Hz, and the Frequency
Reference is 60 Hz)
•
When
C1-14 ≠ 0.0 Hz
–
C1-01, C1-03, C1-05, C1-07:
Time to accelerate from 0 Hz to
C1-14
–
C1-02, C1-04, C1-06, C1-08, C1-09:
Time to decelerate from
C1-14
to 0 Hz
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...