12.2 A: Initialization Parameters
YASKAWA
SIEPC71061753A GA500 Technical Manual
467
The drive saves the parameters in
as User Parameters.
Table 12.17 Parameters Saved as User Parameters with the Traveling Preset
User Parameter No.
Parameter No. Saved
Name
A2-01
b1-01
Frequency Reference Selection 1
A2-02
C1-01
Acceleration Time 1
A2-03
C1-02
Deceleration Time 1
A2-04
C6-02
Carrier Frequency Selection
A2-05
d1-01
Reference 1
A2-06
d1-02
Reference 2
A2-07
d1-03
Reference 3
A2-08
E2-01
Motor Rated Current (FLA)
A2-09
H1-05
Terminal S5 Function Selection
A2-10
H1-06
Terminal S6 Function Selection
A2-11
H2-01
Term MA,MB,MC Function Selection
A2-12
L1-01
Motor Overload (oL1) Protection
8 : Conveyor 2
The drive automatically sets the parameters in
for a conveyor 2 application.
Table 12.18 Best Parameter Settings for Conveyor 2 Application
No.
Name
Optimal Value
A1-02
Control Method Selection
0: V/f Control
C1-01
Acceleration Time 1
3.0 s
C1-02
Deceleration Time 1
3.0 s
C6-01
Normal / Heavy Duty Selection
0: Heavy Duty Rating
L3-04
Stall Prevention during Decel
7: Overexcitation/High Flux 3
n3-13
OverexcitationBraking (OEB) Gain
1.40
n3-21
HSB Current Suppression Level
150
The drive saves the parameters in
as User Parameters.
Table 12.19 Parameters Saved as User Parameters with the Conveyor 2 Preset
User Parameter No.
Parameter No. Saved
Name
A2-01
A1-02
Control Method Selection
A2-02
b1-01
Frequency Reference Selection 1
A2-03
b1-02
Run Command Selection 1
A2-04
C1-01
Acceleration Time 1
A2-05
C1-02
Deceleration Time 1
A2-06
E2-01
Motor Rated Current (FLA)
A2-07
L3-04
Stall Prevention during Decel
A2-08
n3-13
OverexcitationBraking (OEB) Gain
A2-09
n3-21
HSB Current Suppression Level
■
Notes for Elevator Applications
When using the drive for elevator applications, read the safety descriptions and precautions, and safely and
correctly use the device.
Conditions to Open and Close the Brake
Set
L4-07 = 0 [Speed Agree Detection Selection = No Detection during Baseblock]
to open and close the holding
brake.
When
L4-07 = 1 [Detection Always Enabled]
, the output frequency increases when you input the Run command
although the external baseblock command is input. Because of this, speed detection operates and will open the
brake signal.
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...