![YASKAWA CIPR-GA50C series Technical Manual Download Page 450](http://html2.mh-extra.com/html/yaskawa/cipr-ga50c-series/cipr-ga50c-series_technical-manual_3241765450.webp)
11.22 Parameters Changed by PM Motor Code Selection
450
YASKAWA
SIEPC71061753A GA500 Technical Manual
Table 11.14 SSR1 Series Motor Code Setting for Specification of 200 V at 1450 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection
-
130B
130D
130E
130F
1310
Voltage Class
V
200
200
200
200
200
Capacity
kW
7.5
11
15
18.5
22
Motor Rotation Speed
min
-1
1450
1450
1450
1450
1450
E5-02
PM Motor Rated Power
kW
7.5
11.0
15.00
18.50
22.00
E5-03
PM Motor Rated Current (FLA)
A
27.71
39.6
55.5
65.6
75.1
E5-04
PM Motor Pole Count
-
6
6
6
6
6
E5-05
PM Motor Resistance (ohms/
phase)
Ω
0.184
0.099
0.075
0.057
0.041
E5-06
PM d-axis Inductance (mH/
phase)
mH
6.91
4.07
3.29
2.53
1.98
E5-07
PM q-axis Inductance (mH/
phase)
mH
7.66
4.65
3.84
3.01
2.60
E5-09
PM Back-EMF Vpeak (mV/(rad/
s))
mVs/rad
335.0
303.9
311.2
300.9
327.7
E5-24
PM Back-EMF L-L Vrms (mV/
rpm)
mV/min
-1
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
72.5
72.5
72.5
72.5
72.5
E1-05
Maximum Output Voltage
V
190.0
190.0
190.0
190.0
190.0
E1-06
Base Frequency
Hz
72.5
72.5
72.5
72.5
72.5
E1-09
Minimum Output Frequency
Hz
3.6
3.6
3.6
3.6
3.6
L3-24
Motor Accel Time @ Rated
Torque
s
0.084
0.096
0.085
0.080
0.122
n5-02
Motor Inertia Acceleration Time
s
0.084
0.096
0.085
0.080
0.122
n8-49
Heavy Load Id Current
%
-6.0
-9.3
-10.7
-13.2
-15.7
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Table 11.15 SSR1 Series Motor Code Setting for Specification of 400 V at 1450 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection
-
1332
1333
1335
1336
1338
133A
Voltage Class
V
400
400
400
400
400
400
Capacity
kW
0.4
0.75
1.5
2.2
3.7
5.5
Motor Rotation Speed
min
-1
1450
1450
1450
1450
1450
1450
E5-02
PM Motor Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
E5-03
PM Motor Rated Current
(FLA)
A
0.94
1.56
2.81
4.27
6.98
10.21
E5-04
PM Motor Pole Count
-
6
6
6
6
6
6
E5-05
PM Motor Resistance (ohms/
phase)
Ω
12.760
7.421
4.825
2.656
1.353
0.999
E5-06
PM d-axis Inductance (mH/
phase)
mH
128.60
85.11
58.87
46.42
31.73
26.20
E5-07
PM q-axis Inductance (mH/
phase)
mH
166.96
113.19
80.59
60.32
40.45
30.94
E5-09
PM Back-EMF Vpeak (mV/
(rad/s))
mVs/rad
528.6
544.2
568.5
572.8
562.9
587.6
E5-24
PM Back-EMF L-L Vrms
(mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
E1-05
Maximum Output Voltage
V
380.0
380.0
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
E1-09
Minimum Output Frequency
Hz
3.6
3.6
3.6
3.6
3.6
3.6
L3-24
Motor Accel Time @ Rated
Torque
s
0.098
0.071
0.066
0.087
0.085
0.072
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...