![YASKAWA CIPR-GA50C series Technical Manual Download Page 539](http://html2.mh-extra.com/html/yaskawa/cipr-ga50c-series/cipr-ga50c-series_technical-manual_3241765539.webp)
YASKAWA
SIEPC71061753A GA500 Technical Manual
539
Set
C6-03 [Carrier Frequency Upper Limit]
,
C6-04
, and
C6-05 [Carrier Freq Proportional Gain]
to make the
carrier frequency change linearly with the output frequency.
Note:
The drive detects
oPE11 [Carrier Frequency Setting Error]
when these conditions are correct at the same time:
•
C6-04 ≥ C6-03
•
C6-05 ≥ 6
■
C6-05: Carrier Freq Proportional Gain
No.
(Hex.)
Name
Description
Default
(Range)
C6-05
(0227)
Carrier Freq Proportional
Gain
Sets the proportional gain for the carrier frequency. Set
C6-02 = F [Carrier Frequency Selection
= User Defined (C6-03 to C6-05)]
to set this parameter.
Determined by C6-02
(0 - 99)
Set
C6-03 [Carrier Frequency Upper Limit]
,
C6-04 [Carrier Frequency Lower Limit]
, and
C6-05
to make the
carrier frequency change linearly with the output frequency.
■
C6-09: Carrier Freq at Rotational Tune
No.
(Hex.)
Name
Description
Default
(Range)
C6-09
(022B)
Carrier Freq at Rotational
Tune
Sets the Auto-Tuning carrier frequency. Usually it is not necessary to change this setting.
0
(0, 1)
If
C6-09 = 0
and you do Auto-Tuning on a high frequency motor or low impedance motor, it can cause
oC
[Overcurrent]
. To prevent
oC
, increase the carrier frequency value, set
C6-09 = 1
, then do Auto-Tuning.
The procedure to set the carrier frequency when the
A1-02 [Control Method Selection]
setting changes.
•
When
A1-02 = 2 [OLV]
, set
C6-02 = F [Carrier Frequency Selection = User Defined (C6-03 to C6-05)]
and
then increase the value set to
C6-03 [Carrier Frequency Upper Limit]
.
•
When
A1-02 = 5 or 6 [OLV/PM or AOLV/PM]
, use
C6-02
to increase the carrier frequency.
0 : 5 kHz
Note:
When
A1-02 = 5 or 6
, the carrier frequency is 2 kHz.
1 : Use C6-03
Note:
When
A1-02 = 5 or 6
, the carrier frequency is the value set to
C6-02
.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...