11.22 Parameters Changed by PM Motor Code Selection
446
YASKAWA
SIEPC71061753A GA500 Technical Manual
No.
Name
Unit
Motor Code (setting value of E5-01)
E1-05
Maximum Output Voltage
V
200.0
200.0
200.0
200.0
E1-06
Base Frequency
Hz
240
240
240
240
E1-09
Minimum Output Frequency
Hz
12
12
12
12
L3-24
Motor Accel Time @ Rated
Torque
s
0.137
0.132
0.132
0.122
n5-02
Motor Inertia Acceleration
Time
s
0.137
0.132
0.132
0.122
n8-49
Heavy Load Id Current
%
0
0
0
0
◆
Yaskawa SMRD Series SPM Motors
Table 11.7 SMRD Series Motor Code Setting for Specification of 200 V at 1800 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection
-
3000
3001
3002
Voltage Class
V
200
200
200
Capacity
kW
0.1
0.2
0.4
Motor Rotation Speed
min
-1
1800
1800
1800
E5-02
PM Motor Rated Power
kW
0.1
0.2
0.4
E5-03
PM Motor Rated Current (FLA)
A
0.64
1
1.9
E5-04
PM Motor Pole Count
-
6
6
6
E5-05
PM Motor Resistance (ohms/phase)
Ω
17.200
9.960
3.590
E5-06
PM d-axis Inductance (mH/phase)
mH
33.20
19.40
11.90
E5-07
PM q-axis Inductance (mH/phase)
mH
33.20
19.40
11.90
E5-09
PM Back-EMF Vpeak (mV/(rad/s))
mVs/rad
0.0
0.0
0.0
E5-24
PM Back-EMF L-L Vrms (mV/rpm)
mV/min
-1
59.1
69.8
75.9
E1-04
Maximum Output Frequency
Hz
90.0
90.0
90.0
E1-05
Maximum Output Voltage
V
200.0
200.0
200.0
E1-06
Base Frequency
Hz
90.0
90.0
90.0
E1-09
Minimum Output Frequency
Hz
9.0
9.0
9.0
L3-24
Motor Accel Time @ Rated Torque
s
0.100
0.100
0.100
n5-02
Motor Inertia Acceleration Time
s
0.100
0.100
0.100
n8-49
Heavy Load Id Current
%
0.0
0.0
0.0
Table 11.8 SMRD Series Motor Code Setting for Specification of 200 V at 3600 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection
-
3101
3102
3103
Voltage Class
V
200
200
200
Capacity
kW
0.2
0.4
0.75
Motor Rotation Speed
min
-1
3600
3600
3600
E5-02
PM Motor Rated Power
kW
0.20
0.40
0.75
E5-03
PM Motor Rated Current (FLA)
A
1.50
2.60
4.20
E5-04
PM Motor Pole Count
-
6
6
6
E5-05
PM Motor Resistance (ohms/
phase)
Ω
3.340
1.560
0.541
E5-06
PM d-axis Inductance (mH/phase)
mH
6.58
3.82
2.24
E5-07
PM q-axis Inductance (mH/phase)
mH
6.58
3.82
2.24
E5-09
PM Back-EMF Vpeak (mV/(rad/
s))
mVs/rad
0.0
0.0
0.0
E5-24
PM Back-EMF L-L Vrms (mV/
rpm)
mV/min
-1
26.3
31.0
32.9
E1-04
Maximum Output Frequency
Hz
180.0
180.0
180.0
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...