Using DiPro 1500 in Program mode
DiPro 1500 User Manual
74
Ch 5
1092000
To set the "ready on" and "ready off" angles:
1. Use the angle keys to move the bar along the ruler marked in degrees. You
move the left edge of the bar with the "on" keys. You move the right edge of
with the "off" keys.
See "Angle keys" under "Using the keyboard" in Chapter 3 for step-by-step
instructions on how to move the bar. The display below shows a green
sensor with the ready signal set to 190° on, 300° off.
sensor name
SENSOR 1 PART EJECTION GREEN
0
90
180
270
360
USE THE ANGLE KEYS
TO SET THE READY
PRESS RESET WHEN
DONE
sensor type
ready signal
bar shows
ready signal
graphically
190
300
ON
OFF
READY
2. After setting the ready signal, press RESET to go back to your list of
sensors.
Setting counter value for green special sensor
After setting the sensor type for a green special sensor, you will see the following
display. You can set the maximum number of strokes that the press can make
without this sensor actuating. The preset limit is 99. Use your up (^) or down (
v
)
cursor keys to adjust the value. Then press the reset key when you are done.
TOOL # 4400
SENSOR 6
USE CURSOR KEYS TO CHANGE # OF STROKES
PRESS THE RESET KEY WHEN YOU ARE DONE
GREEN SPECIAL
SLUG DETECTION
THIS SENSOR MUST TURN ON
AT LEAST ONCE EVERY
number of
strokes to
set for green
special sensor
can be
from 1 to 99
11
STROKES
CAUTION
The green special sensor is not foolproof. It is possible that an undesirable
number of slugs could conceivably stack up in an ejection hole, while still
satisfying a green special sensor's requirements
Summary of Contents for dipro 1500
Page 9: ...Table of Contents DiPro 1500 User Manual vi TOC 1092000 ...
Page 59: ...DiPro 1500 Installation DiPro 1500 User Manual 50 Ch 2 1092000 ...
Page 77: ...Using DiPro 1500 in Initialization mode DiPro 1500 User Manual 68 Ch 4 1092000 ...
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......