Using DiPro 1500 in Program mode
DiPro 1500 User Manual
73
Ch 5
1092000
TOOL # 4400
SENSOR 1
USE CURSOR KEYS TO CHANGE SELECTION
PRESS ENTER TO SELECT, RESET WHEN DONE
PART EJECTION
EMERGENCY STOP
TOP STOP
To set stop type for red, yellow, green, green quick check, and green constant,
select the setting you want for the sensor—emergency stop or top stop.
For red and yellow sensors, you are done making settings. You will go back to the
display listing the six sensors. You can set another sensor. Go to "Setting the other
sensors for the tool".
The following explains how to set the ready signal for green, green quick check,
and green constant sensors and the counter for green special sensors.
Setting the ready signal for a green sensor
After selecting stop type for a green sensor, you will see the display shown below.
You can set the ready on angle and ready off angle (the ready signal). The ready
signal is the degrees of the stroke where the sensor must actuate or DiPro sends the
stop signal to the press.
SENSOR 1 PART EJECTION GREEN
USE THE ANGLE KEYS
TO SET THE READY.
PRESS RESET WHEN
DONE
0
90
180
270
360
0
0
ON
OFF
READY
You set the ready signal so it is a little longer than the sensor's actuation time for
green and green quick check sensors. You set it so it is a little shorter than the
sensor's actuation time for green constant sensors. See Chapter 1 for an explanation
of the different types of green sensors.
NOTE:
If you are not sure what to make the ready signal, estimate it. You can
adjust the setting later in Run mode after you run the press. DiPro will display the
sensor actuation time in degrees in Run mode.
Summary of Contents for dipro 1500
Page 9: ...Table of Contents DiPro 1500 User Manual vi TOC 1092000 ...
Page 59: ...DiPro 1500 Installation DiPro 1500 User Manual 50 Ch 2 1092000 ...
Page 77: ...Using DiPro 1500 in Initialization mode DiPro 1500 User Manual 68 Ch 4 1092000 ...
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......