Using DiPro 1500 in Initialization mode
DiPro 1500 User Manual
62
Ch 4
1092000
INITIALIZATION
MENU
USE CURSOR KEYS TO SELECT, ENTER TO SET.
SWITCH TO RUN WHEN DONE.
RESOLVER ZERO
POSITION SENSOR
COMMUNICATIONS
SELECT CAM NAMES
SECURITY ACCESS
This is the Initialization Menu—the first display in Initialization mode. From this
display, you can call up all the other displays in Initialization mode and carry out your
tasks. Each choice is described next.
To get out of Initialization mode
To get out of Initialization mode, you must turn the Program/Run
switch to "Run". Make sure the Initialization menu is on your screen
first. You will go into Program mode.
If the Initialization menu was not on your screen when you switched
(you were farther down in Initialization mode), keep pressing the
RESET key until you go back to the Initialization menu. Then the
new mode will instantly appear. Get in the habit of always backing
out of one mode before entering another mode.
Resolver zero
When you select "resolver zero" on the Initialization menu, you will see the current zero
position of the resolver. The number displayed is the position (in degrees) of the resolver
when the press is at top dead center. The number should be zero (or close to it) when the
resolver is properly installed and zeroed.
How to use "resolver zero" is fully explained in Chapter 2—Installation. You only use
this menu item when installing the resolver or replacing the resolver. Otherwise you
never need to check what resolver zero is. For more information on zeroing the resolver,
see "Zero resolver" in Chapter 2.
SELECT = HIG ENTER
When we say SELECT in this manual, it means highlight the item and press ENTER.
Position sensor
This choice on the Initialization menu allows you to enable the position sensor if one is
used. (Using a position sensor is optional.) This choice also allows you to check that the
position sensor is working properly after it is installed.
If you do not have a position sensor installed, the only time you need to use this choice is
to check that the position sensor is turned off. You should check the setting if DiPro stops
the press and you get this error message: "position sensor incorrect". This means you
need to turn the position sensor off as described below.
Summary of Contents for dipro 1500
Page 9: ...Table of Contents DiPro 1500 User Manual vi TOC 1092000 ...
Page 59: ...DiPro 1500 Installation DiPro 1500 User Manual 50 Ch 2 1092000 ...
Page 77: ...Using DiPro 1500 in Initialization mode DiPro 1500 User Manual 68 Ch 4 1092000 ...
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......