DiPro 1500 Installation
DiPro 1500 User Manual
27
Ch 2
1092000
Table 2-1. DiPro RCB to Connector TB101
*
Provides power for electronic sensors used in inputs 1,2, and 3 (Lumberg connectors); 12 Vdc, 100 mA total
Brown
Purple
Orange
Yellow
Green
Blue
Black
Red *
1
2
3
4
5
6
GND
NONE
1
2
3
4
5
6
11
9
Sensor 1
GND
Sensor
power
Sensor 2
Sensor 3
Sensor 4
Sensor 5
Sensor 6
Wire
RCB
Jack #
Connector
TB101
For
Connecting DiPro Sensor Interface or Wintriss
Sensor Interface to DiPro 1500
If you are connecting DiPro Sensor Interface or Wintriss Sensor Interface to your DiPro
1500, connect the cable as shown in Table 2-2. Notice that while there are 8 inputs for
sensors at DiPro Sensor Interface or Wintriss Sensor Interface, DiPro 1500 has only six
inputs for sensors. Therefore, you will have two unused wires in your WSI cable. Refer
to the applicable user manual for complete installation and operating instructions.
Table 2-2. Wiring connections from DSI
or
WSI to DiPro 1500 TB101
OUT 1 (1)
OUT 2 (2)
OUT 3 (3)
OUT 4 (4)
OUT 5 (5)
OUT 6 (6)
GND (9)
GND (10)
OUT 7 (7)
OUT 8 (8)
INPUT 1 (1)
INPUT 2 (2)
INPUT 3 (3)
INPUT 4 (4)
INPUT 5 (5)
INPUT 6 (6)
unused
unused
GND (11)
unused
TB101 (Pin #)
Wire
Black
Brown
Red
Orange
Yellow
Green
Blue
OUTPUT 1 (2)
OUTPUT 2 (3)
OUTPUT 3 (4)
OUTPUT 4 (5)
OUTPUT 5 (6)
OUTPUT 6 (7)
unused
unused
GND (10)
unused
WSI TB30 (Pin #)
DSI TB223 (Pin #)
Summary of Contents for dipro 1500
Page 9: ...Table of Contents DiPro 1500 User Manual vi TOC 1092000 ...
Page 59: ...DiPro 1500 Installation DiPro 1500 User Manual 50 Ch 2 1092000 ...
Page 77: ...Using DiPro 1500 in Initialization mode DiPro 1500 User Manual 68 Ch 4 1092000 ...
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......