DiPro 1500 Fault messages
DiPro 1500 User Manual
102
Ch 7
1092000
Green quick check sensor came on outside ready
SENSOR 2 [sensor name]
THIS GREEN QUICK CHECK SENSOR WENT ON
OUTSIDE ITS READY AT _____ DEGREES
Problem:
A green quick check sensor came on or stayed on outside the ready
signal. The stroke angle where the sensor was first detected on outside
the ready is listed.
Remedy:
Check for the malfunction the sensor is supposed to detect (part
ejection problem, misfeed, etc.) Check for a part wedged against the
sensor, a shorted sensor, a pinched wire, or other cause that would
keep the sensor on or cause it to go on outside its ready signal. Make
sure the ready signal is set correctly.
Fault message for yellow sensors
SENSOR 5 [sensor name]
YELLOW FAULT, THIS N/O SENSOR HAS BEEN
GROUNDED AT DEGREES
Problem:
A yellow sensor turned on (there was a contact closure to ground).
When this message appears, the angle where the condition was
detected is also shown on the LCD display.
Remedy:
Check for the press or equipment malfunction that the sensor was
supposed to detect. If none has occurred, check for a shorted sensor or
pinched wire.