Introduction to DiPro 1500
DiPro 1500 User Manual
14
Ch 1
1092000
Specifications
Equipment
Main enclosure 12" x 10.25" x 4" (30.5 x 26 x 10.2 cm), NEMA 12, shock mounted
Resolver: 0.75" (1.9 cm) keyed shaft; rated shaft loading: 200 lb axial, 200 lbs radial
Electrical
Input: 120/240 Vac 50/60 Hz, 15 VA
Input check circuit: 12-250 Vac or Vdc
Speed
7-800 SPM; 14-1600 SPM optional at reduced accuracy
Accuracy
±.66° (±1.33° for high speed version)
Counters
Good parts, batch: Preset for maximum count, set to 7 digits
Number of hits on tool counter: Resettable to 0 after tool regrind; counts all hits on tool
Display
8 line x 40 character LCD
3-digit LED readout — displays SPM when press running, crank angle when stopped
Memory
Executive program: EPROM
User program: battery on chip static RAM; allows storage of settings for 200 tools
Inputs
Inputs for resolver, position sensor (resolver slippage detection), input check circuit,
remote reset input, setup mode input
Sensor inputs 1, 2, 3: low impedance
Sensor inputs 4, 5, 6: high impedance
Sensor "on" is ground signal
Electronic sensors NPN only
Outputs
Power for electronic sensors: 12Vdc min, 100 mA total
Programmable cam switch channels: 4 or 8
Top stop, emergency stop: ratings 0-5A resistive
@ 120V max (AC or DC); Normally open—Held closed
(fault condition or power off opens relay(s))
Options
•
RCB: 4.56" x 2.56" x 4.06" (11.6 x 6.5 x 10.3)
•
Programmable cam output assembly (NEMA 12; holds up to 8 cams)
• Enclosure: 9" x 11" x 3.5" (22.9 x 27.9 x 8.9 cm) shock-mounted
• Relay SPDT 0-3A resistive @ 240V
• DC solid state SPST 2A @ 5-60 Vdc
• AC solid state SPST 1A @ 70-250 Vac
• Spectrum-style cam output assembly (NEMA 12; holds up to 4 cams)
• Enclosure: 6" x 8" x 4" (15.2 x 20.3 x 10.2 cm) shock-mounted
• Relay SPDT 0-3A resistive @ 120V
• DC solid state SPST 3A @ 3-60 Vdc
• AC solid state SPST 3A @ 12-280 Vac
• Firmware for SFI™, Servo Feed Interface to integrate electronic/digital servofeed with DiPro
1500
*
• Firmware for AutoSave™ which allows DiPro 1500 to save AutoSet™ series load analyzer
setpoints
*
• Firmware to connect DiPro 1500 to PACNet® pressroom monitoring software network *
• Firmware to connect DiPro 1500 to PACNet RSR® Remote Storage and Retrieval provides
unlimited setup memory (RSR can be purchased as part of PACNet or separately) *
* It may not be possible to combine two or more firmware options.
Summary of Contents for dipro 1500
Page 9: ...Table of Contents DiPro 1500 User Manual vi TOC 1092000 ...
Page 59: ...DiPro 1500 Installation DiPro 1500 User Manual 50 Ch 2 1092000 ...
Page 77: ...Using DiPro 1500 in Initialization mode DiPro 1500 User Manual 68 Ch 4 1092000 ...
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......