DiPro 1500 Installation
DiPro 1500 User Manual
41
Ch 2
1092000
If your screen is blank, first check the setting for the contrast adjust knob to the right of
the screen. If it is is all the way to the left, the screen is completely dimmed. Turn the
knob one quarter turn to the right. You will see the menu now. Adjust the knob for best
viewing.
If the contrast adjust knob was not the problem, there is probably a problem with power
to DiPro. Turn power to DiPro off and recheck all power connections. If you still cannot
get the Initialization Menu, call the technical staff at Data Instruments for assistance.
If you got an error message on your screen when you turned power on, first press the
RESET key a couple times to clear the error message. If the message still appears, go to
Chapter 7 in this manual and find the section describing that error message. Follow the
instructions there for correcting the problem. If the error message is not described there,
or you cannot fix the problem, call Data Instruments' technical advisors.
Zero Resolver
With the Initialization Menu on your screen, you can now zero the resolver.
Important:
the press must be at top dead center —0° ± 2°—before you zero.
If you set the resolver to
zero degrees when the press is, say, at 160°, your timing settings will be way off.
If your press is at TDC
If you set the press to TDC (0° ±2°) before starting the installation and have not moved
the ram, go to the instructions for zeroing.
If your press is not at TDC
If the ram is not at TDC, you must inch the press to 0°±2°. To do this now, you have to
load settings for a tool. DiPro is now connected to your stop circuits, so you can no
longer run the press without settings for a tool loaded. So go into Program mode (see
Chapter 5) and create some settings for a tool. As long as you do not have a die in the
press or sensors connected, it does not matter what settings you use. You can disable
sensors so DiPro does not stop the press due to a sensor fault. See Chapter 5 for how to
make settings. (This is why we told you to become familiar with the DiPro displays
before starting installation).
After settings are loaded, set the program/run key to run. Inch the press to 0° ±2°. Do not
rely on the readout to tell you where TDC is. This is inaccurate until the resolver is
zeroed. Use a dial indicator or other means to determine 0°. Once you are at 0°, go back
to Initialization mode. Then go to the instructions below for zeroing the resolver.
To zero the resolver:
1. Select "resolver zero" from the Initialization menu. This is the first choice on the
menu. To select, use the cursor keys to move the bar over the words "resolver
zero". (The bar may already be there.) Then press ENTER.
2. You will see the following display:
Summary of Contents for dipro 1500
Page 9: ...Table of Contents DiPro 1500 User Manual vi TOC 1092000 ...
Page 59: ...DiPro 1500 Installation DiPro 1500 User Manual 50 Ch 2 1092000 ...
Page 77: ...Using DiPro 1500 in Initialization mode DiPro 1500 User Manual 68 Ch 4 1092000 ...
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......