DiPro 1500 Installation
DiPro 1500 User Manual
48
Ch 2
1092000
Check Emergency stop circuit
7. Clear the error message by pressing RESET. Go to Programming mode and set
the stop type for your sensor to Emergency stop. Reload the tool number. Go into
Run mode..
8. Run the press again and trip the sensor to simulate a fault. Check that the press
stops immediately and that an error message is displayed on the screen. If all this
occurs, go to Step 9.
If the press did not stop immediately, there is a problem in your Emergency stop
circuit. Recheck all wiring and trace the cause of the problem. Do not continue
with this procedure until you get an immediate stop when you trip the sensor.
Check cam channels (if installed)
9. If you have the programmable cam switch installed, turn DiPro off. Plug in the
connector to TB301. (Remember we told you to unplug this earlier). Go into Run
mode and create some settings for your cam channels. Load the tool settings, go
intor Run mode, and run the press. Ensure that the equipment (feed, blow off,
etc.) controlled by each channel is working properly according to the settings you
made.
10.
If you got to this step, everything is working right. Clear any error message by
pressing RESET. Delete the test settings. You can now load a tool, create settings
for the tool, and begin to make parts using your new DiPro 1500.
Summary of Contents for dipro 1500
Page 9: ...Table of Contents DiPro 1500 User Manual vi TOC 1092000 ...
Page 59: ...DiPro 1500 Installation DiPro 1500 User Manual 50 Ch 2 1092000 ...
Page 77: ...Using DiPro 1500 in Initialization mode DiPro 1500 User Manual 68 Ch 4 1092000 ...
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......