Using DiPro 1500 in Initialization mode
DiPro 1500 User Manual
67
Ch 4
1092000
Example
You want to prevent personnel from adjusting sensors in Run mode. Select
"Program and Run mode" next to "adjust sensors".
You will now see this display:
ADJUST SENSORS:
PROGRAM MODE ONLY
USE CURSOR KEYS TO CHANGE SELECTION
PRESS ENTER TO CHANGE, RESET WHEN DONE
LOAD TOOL #: PROGRAM AND RUN MODES
ADJUST CAMS: PROGRAM AND RUN MODES
ADJUST COUNTERS: PROGRAM AND RUN MODES
RESET MODE: PROGRAM AND RUN MODES
DISABLE SENSORS: PROGRAM AND RUN MODES
Personnel can now adjust sensors in Program mode only.
Locking Reset mode
Setting Reset mode to "Program only" means personnel cannot reset DiPro in Run mode
after a malfunction occurs that stops the press. DiPro must be switched to Program mode
to clear the fault message. Pushing the Reset key in Program mode clears the fault. The
press can be run again once DiPro is switched back to Run mode.
Preventing the resetting of faults in Run mode is useful if you want one person to record
or be aware of all faults that occur. This person would have the program/run key. Only he
could reset faults by turning the key to "program" and pressing the Reset key.