DiPro 1500 Fault messages
DiPro 1500 User Manual
105
Ch 7
1092000
Messages displayed for equipment or software
problems
These messages tell you that something is wrong with the DiPro resolver, input cir-
cuit, or position sensor or with the way your press is running. Some fault messages
indicate there is a problem with the tool number or that a tool number is not loaded.
These messages can also indicate an internal problem with DiPro 1500 itself.
If you cannot correct the problem yourself after reading the remedy for the problem
below, contact a Data Instruments representative. Whenever you need help, just re-
member that we have expert technical service representatives available to help you
by phone. Never hesitate to call Data Instruments if you have trouble with DiPro
1500.
Once you have corrected the problem, press RESET. If the problem is corrected,
you will be able to run the press again. If not, you will get the same fault message.
Input failure
INPUT CHECK CIRCUIT FAILURE
THE RESOLVER TURNED FIVE TIMES WITHOUT
INPUT CHECK BEING TURNED ON
Problem:
The resolver turned five times (meaning the press was running), but
DiPro received no signal from the input check circuit.
Remedy:
The input check circuit has not been connected or wired properly. If
this message occurs when the press stops, your press is taking more
than five revolutions to stop after the brake is activated. You should
check your brake for wear. For wiring the input check circuit, see
"Connecting AC wiring, stop circuits and input check circuit" in
Chapter 2.
Summary of Contents for dipro 1500
Page 9: ...Table of Contents DiPro 1500 User Manual vi TOC 1092000 ...
Page 59: ...DiPro 1500 Installation DiPro 1500 User Manual 50 Ch 2 1092000 ...
Page 77: ...Using DiPro 1500 in Initialization mode DiPro 1500 User Manual 68 Ch 4 1092000 ...
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......