DiPro 1500 Fault messages
DiPro 1500 User Manual
108
Ch 7
1092000
Resolver failure
ANGLE RESOLVER FAILURE
THE PRESS IS GOING FASTER THAN 800 SPM
OR THE ANGLE RESOLVER HAS FAILED OR THE
CONNECTIONS FROM THE RESOLVER ARE BROKEN.
Problem:
As the message states, the press is going faster than 800 SPM (the top
rating for DiPro) or the resolver failed. It may just be that wiring in the
resolver circuit to DiPro is loose or bad.
NOTE:
If you have a DiPro 1500 allowing press speeds up to 1600
spm, the message will state 1600 spm instead of 800.
Remedy:
If DiPro's rated press speed is exceeded, reduce speed. If not, check
the resolver wiring and connections for shorts, breaks, or loose
connections. See Chapter 2 "Mounting the resolver" for complete
information about resolver wiring. If the wiring is not the problem, the
resolver is probably bad and will have to be replaced.
NOTE:
This fault cannot be cleared by pressing the RESET key. You
must turn DiPro off, then on, to clear the fault.
Tool number checksum incorrect
TOOL NUMBER CHECKSUM INCORRECT
THE INFORMATION CREATED WHEN A TOOL
NUMBER IS LOADED WAS CORRUPTED. RELOAD
THE TOOL NUMBER.
Problem:
The checksum for the tool number loaded when DiPro was turned off
does not match the checksum when DiPro was turned back on. See the
next fault message for more about checksums.
Remedy:
First reload the tool number you want to use. If the error occurs again,
contact Data Instruments technical service advisors.
Summary of Contents for dipro 1500
Page 9: ...Table of Contents DiPro 1500 User Manual vi TOC 1092000 ...
Page 59: ...DiPro 1500 Installation DiPro 1500 User Manual 50 Ch 2 1092000 ...
Page 77: ...Using DiPro 1500 in Initialization mode DiPro 1500 User Manual 68 Ch 4 1092000 ...
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......