Packet Tab
594
This test cycle continues until
the test is stopped by
selecting
Stop
from the
Common Function Buttons,
or by changing the
Action
After Duration
value. value.
Print Options
When a print option is chosen from the Remote Client, the
report is sent to the
System tab's
User Preference
screen. If the Current Printer
is configured for
Prompt Each Time
, then a Windows Print
dialog box appears for you to choose between your PC's
default printer or another printer listed in the drop-down
menu.
Record Options
When a Record option is chosen, the results are saved to a
file with one of the following extensions:
•
.stat
- Results Report. A statistics report of the
received Errors, Alarms, Pointer Analysis, and Signal
Status functions.
•
.evt
- Event Report. A detailed summary of received
Errors, Alarms and Pointer event activities.
The file naming convention is:
XX S#-P#-hhmmss.<file
extension>
(where
XX
is the Protocol Processor
name,
S#
is the Slot#,
P#
is the Port#,
hh
is Hours,
mm
is Minutes,
ss
is Seconds).
For example, a file named "
SONET S2-P1-155815.
"
represents a
SONET
statistics report from
Port 1
on
Slot 2
and was recorded at
15:58:15
.
To determine how long a test will run, refer to
Duration
.
After configuring the Duration, you must select
order for the Timed Test to begin.
MPA_e_manual_D07-00-129P_RevA00
Summary of Contents for MPA
Page 2: ...MPA_e_manual_D07 00 129P_RevA00...
Page 10: ...MPA_e_manual_D07 00 129P_RevA00...
Page 82: ...MPA_e_manual_D07 00 129P_RevA00...
Page 110: ...MPA_e_manual_D07 00 129P_RevA00...
Page 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Page 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Page 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Page 748: ...MPA_e_manual_D07 00 129P_RevA00...
Page 796: ...MPA_e_manual_D07 00 129P_RevA00...