Packet Tab
550
Latency Min/Max/Avg
- Reports how long it takes for the test
frames to traverse the network and return to the unit. The
values that appear are in milliseconds.
If the test set is looped to itself with a short patch cable, the
latency may appear as 0 ms.
Start/Stop Test
Starts and stops the Through Put test. The button toggles
between Start (when a test is not running) and Stop (when a
test is running).
The following list of tasks demonstrate how to configure and test each of the RFC-
2544 benchmark tests.
•
To
Configure the RFC-2544 test
•
To run an
RFC-2544 Thru Put
•
To run an
RFC-2544 Frame Loss
•
To run an
RFC-2544 B2B Burst
RFC Tests - Frame Loss Test
This is an RFC 2544 benchmark test. Its purpose is to determine the number of frames
lost by looping a stream (with a specified frame size) through the network at varying
transmit frame rates. Select
The following options appear on the Frame Loss screen:
Option
Description
Stream ID
Displays the ID number of the stream that will be used for the
RFC test.
is configured from the RFC Tests - Conf
screen.
MPA_e_manual_D07-00-129P_RevA00
Summary of Contents for MPA
Page 2: ...MPA_e_manual_D07 00 129P_RevA00...
Page 10: ...MPA_e_manual_D07 00 129P_RevA00...
Page 82: ...MPA_e_manual_D07 00 129P_RevA00...
Page 110: ...MPA_e_manual_D07 00 129P_RevA00...
Page 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Page 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Page 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Page 748: ...MPA_e_manual_D07 00 129P_RevA00...
Page 796: ...MPA_e_manual_D07 00 129P_RevA00...