![VeEX MPA User Manual Download Page 210](http://html2.mh-extra.com/html/veex/mpa/mpa_user-manual_3826057210.webp)
OTN Tab
210
•
TCM #1 Alarm Reporting
(Tandem Connection Monitoring #1) - Enabled with
or without TIM Alarm Reporting
•
TCM #2 Alarm Reporting
(Tandem Connection Monitoring #2) - Enabled with
or without TIM Alarm Reporting
•
TCM #3 Alarm Reporting
(Tandem Connection Monitoring #3) - Enabled with
or without TIM Alarm Reporting
•
TCM #4 Alarm Reporting
(Tandem Connection Monitoring #4) - Enabled with
or without TIM Alarm Reporting
•
TCM #5 Alarm Reporting
(Tandem Connection Monitoring #5) - Enabled with
or without TIM Alarm Reporting
•
TCM #6 Alarm Reporting
(Tandem Connection Monitoring #6) - Enabled with
or without TIM Alarm Reporting
•
OPU PLM Alarm Reporting
(Payload Label Mismatch) - Enabled or Disable
Alarm Reporting
•
OPU Out of Frequency Threshold
- Sets the threshold (in ppm) for which the
OPU:Frequency Wide alarm
occurs, based on the measured OPU Justify
Frequency Offset. The default value is 0.0 (Disabled).
•
Signal Auto-Recovery Method
- This is used as an attempt to recover the
signal in the event the OTN's client processor signal (SONET/SDH tab, Packet
tab, etc) is in an alarm state such as Loss of Frame or Loss of Link.
•
By setting this to
Default
, the SDH processor will refresh every 30
seconds or so, which gives the client processor an opportunity to re-
acquire a good framing or link.
•
By setting this to
Alternate
, then the SDH processor will not try to auto-
recover (refresh) when the client processor framing or link state is bad.
You may need to force an LOS event (and then clear the LOS event) after
the signal failure has been resolved, for the client to re-acquire client
framing or link state.
•
Signal Auto-Recovery Method is only supported on the MPM-10G card.
OTN Receive - Set / Set 3
Use the Set 1, Set 2 and Set 3 screens to configure the OTN Receive parameters.
The Set 3 screen Enables and Disables the following A/D alarm reporting parameters:
•
A/D ODU PM TIM Alarm Reporting
(A/D ODU SAPI and DAPI - Trace Identifier
Mismatch) - Enabled or Disable Alarm Reporting
MPA_e_manual_D07-00-129P_RevA00
Summary of Contents for MPA
Page 2: ...MPA_e_manual_D07 00 129P_RevA00...
Page 10: ...MPA_e_manual_D07 00 129P_RevA00...
Page 82: ...MPA_e_manual_D07 00 129P_RevA00...
Page 110: ...MPA_e_manual_D07 00 129P_RevA00...
Page 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Page 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Page 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Page 748: ...MPA_e_manual_D07 00 129P_RevA00...
Page 796: ...MPA_e_manual_D07 00 129P_RevA00...