SONET Tab
364
The Path screen displays a detailed breakdown of incoming B3 (Path BIP-8, also known
as Path Coding Violations) and STS Path Remote Error Indicator (REI-P) errors.
The following statistics are reported:
Path - Near End B3 Errors
•
CV
-
Code Violations
. Reports an error count of incoming B3 errors.
•
ES
-
Errored Seconds
. Reports the duration of the incoming B3 errors (in
seconds). This statistic also reports the percentage of errored seconds compared
to the duration of error-free seconds.
•
EFS
-
Error Free Seconds
. Reports the duration of the incoming B3 error free
seconds. This statistic also reports the percentage of error-free seconds
compared to the duration of errored seconds.
•
SES
-
Severely Errored Seconds
. Reports the duration of SES on the incoming
SONET signal. An SES is reported when the number of B3 errors per second
equals or exceeds
2,400 errors per second
, or when an LOS alarm, SEF alarm,
LOF alarm, AIS-L alarm, LOP-P alarm, AIS-P alarm, UNEQ-P alarm is present.
•
UAS
-
Unavailable Seconds
. Reports the number of seconds that the Path layer
was considered unavailable. A Path is considered unavailable when at least 10
consecutive Severely Errored Seconds
occur.
Path Far End REI-P Errors
•
CV
-
Code Violations
. Reports an error count of incoming REI-P errors.
•
ES
-
Errored Seconds
. Reports the duration of the incoming REI-P errors (in
seconds). This statistic also reports the percentage of errored seconds compared
to the duration of error-free seconds.
•
EFS
-
Error Free Seconds
. Reports the duration of the incoming REI-P error
free seconds. This statistic also reports the percentage of error-free seconds
compared to the duration of errored seconds.
•
SES
-
Severely Errored Seconds
. Reports the duration of SES on the incoming
SONET signal. An SES is reported when the number of REI-P errors per second
equals or exceeds
2,400 errors per second
, or when a RDI-P alarm is present.
•
UAS
-
Unavailable Seconds
. Reports the number of seconds that the Path layer
was considered unavailable. A Path is considered unavailable when at least 10
consecutive Severely Errored Seconds
occur.
Perf Monitor - VT Path
MPA_e_manual_D07-00-129P_RevA00
Summary of Contents for MPA
Page 2: ...MPA_e_manual_D07 00 129P_RevA00...
Page 10: ...MPA_e_manual_D07 00 129P_RevA00...
Page 82: ...MPA_e_manual_D07 00 129P_RevA00...
Page 110: ...MPA_e_manual_D07 00 129P_RevA00...
Page 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Page 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Page 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Page 748: ...MPA_e_manual_D07 00 129P_RevA00...
Page 796: ...MPA_e_manual_D07 00 129P_RevA00...