Packet Tab
574
The following error types can be monitored:
Error Type
Description
Code
A Code error or Symbol error is detected in the line encoding
Undersized
A frame whose length is < 64 bytes, with good FCS/CRC
checksum
Invalid FCS
An error in the Frame Check Sequence (CRC checksum),
and whose Frame length is ≥ 64 bytes
Invalid IP
An error in the frame's IP Checksum
Invalid UDP
An error in the frame's UDP Checksum
Runts
A frame whose length is < 64 byte with an FCS error
The following error statistics are displayed:
Statistic
Description
Error
Displays the error type recognized and recorded by the unit.
Count
Displays the number of errors using an 11-digit format.
Errored Seconds
Displays the number of errored seconds.
Average
Displays the average error rate using an N.NNe-N format.