Protocol Tabs
363
Line - Far End REI Errors
•
CV
-
Coding Violations
. Reports an error count of the number of B2 errors
detected by the far-end Line Terminating Equipment (LTE). These errors are
reported back to the unit using the M1 byte of the Line overhead. The M1 byte is
also known as the Line Remote Error Indicator - REI-L. (A CV-LFE was formerly
known as a Line FEBE.)
•
ES
-
Errored Seconds
. This counter reports the number of seconds that an REI-
L alarm is reported
•
EFS
-
Error Free Seconds
. Reports the duration of the incoming REI-L error
free seconds and the percentage of error free seconds compared to the duration
of errored seconds.
•
SES
-
Severely Errored Seconds
. Reports the duration of SES on the incoming
SONET signal. An SES is reported when the number of REI-L errors per second
equals or exceed the
Line SES Threshold
(see table below), or when a Line
Remote Defect Indicator (RDI-L) alarm is present.
•
UAS
-
Unavailable Seconds
. Reports the number of seconds that the Line layer
was considered unavailable. A Line is considered unavailable when at least 10
consecutive Severely Errored Seconds
occur.
Interface
Line SES threshold
OC-768
39,339 errors per second
OC-192
9,835 errors per second
OC-48
2,459 errors per second
OC-12
615 errors per second
OC-3
154 errors per second
OC-1
51 errors per second
Perf Monitor - Path
(Specifically for SONET testing)
MPA_e_manual_D07-00-129P_RevA00
Summary of Contents for MPA
Page 2: ...MPA_e_manual_D07 00 129P_RevA00...
Page 10: ...MPA_e_manual_D07 00 129P_RevA00...
Page 82: ...MPA_e_manual_D07 00 129P_RevA00...
Page 110: ...MPA_e_manual_D07 00 129P_RevA00...
Page 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Page 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Page 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Page 748: ...MPA_e_manual_D07 00 129P_RevA00...
Page 796: ...MPA_e_manual_D07 00 129P_RevA00...