SONET Tab
326
repeats indefinitely and does not contain CRC-7.
The J0 trace is part of the Section Overhead and is known
as the Section trace or J0 byte.
When
TIM Alarm Reportin
g is Enabled, a
TIM-S
alarm
occurs if the incoming J0 trace does not match the Expected
J0 Trace.