Getting Started
29
•
For Ethernet, a standard 10/100/1000BaseT
RJ-45 Ethernet cable
, connected
to a network or directly to a PC
•
For USB, a
USB 2.0 Micro-B
cable
(provided with system)
(Two USB cables are shipped with the new systems; a USB 2.0 Mini-A connector
type for use with the AMC Processor, and a USB 2.0 Micro-B connector type for
use with the MCH)
Option 1: Establish a connection to the MCH via Ethernet (Telnet):
1. To communicate with the MCH via
Telnet
, the MCH’s GbE current IP Address
must be known and responsive to Ping requests.
•
The MCH’s default IP Address is
192.168.0.11
(for units built after of May of
2014)
•
If the MCH’s current IP Address is unknown or does not respond to Ping
requests, then precede to the
USB instructions
2. Launch the
PuTTY
utility, and select the
Telnet
Connection type (
Port #23
).
3.
Enter the MCH’s current
IP Address
into the
Host Name
text box and click
Open
.
MPA_e_manual_D07-00-129P_RevA00