SONET Tab
366
•
UAS
-
Unavailable Seconds
. Reports the number of seconds that the Path layer
was considered unavailable. A Path is considered unavailable when at least 10
consecutive Severely Errored Seconds
occur.
Perf Monitor - BIT
(Specifically for SONET testing)
Bit analysis provides a detailed breakdown for detected Payload Bit errors.
The following statistics are reported:
Payload - BIT Errors
•
CV
-
Coding Violations
. Reports an error count of incoming BIT errors.
•
ES
-
Errored Seconds
. Reports the duration of the incoming BIT errors in
seconds and the percentage of errored seconds compared to the duration of
error free seconds.
•
EFS
-
Error Free Seconds
. Reports the duration of the incoming BIT error free
seconds and the percentage of error free seconds compared to the duration of
errored seconds.
•
SES
-
Severely Errored Seconds
. Reports the duration of SES on the incoming
SONET signal. An SES is reported when the number of BIT errors per second
equals or exceeds
2,400 errors per second
for STS mappings or
600 errors
per second
for VT mappings, or when an LOS alarm, SEF alarm, LOF alarm,
AIS-L alarm, LOP-P alarm, AIS-P alarm, UNEQ-P alarm, UNEQ-V alarm, AIS-V
alarm, LOP-V alarm, or LOM-V alarm is present.
•
UAS
-
Unavailable Seconds
. Reports the number of seconds that the Payload
was considered unavailable. The Payload is considered unavailable when at
least 10 consecutive Severely Errored Seconds
occur.
MPA_e_manual_D07-00-129P_RevA00
Summary of Contents for MPA
Page 2: ...MPA_e_manual_D07 00 129P_RevA00...
Page 10: ...MPA_e_manual_D07 00 129P_RevA00...
Page 82: ...MPA_e_manual_D07 00 129P_RevA00...
Page 110: ...MPA_e_manual_D07 00 129P_RevA00...
Page 134: ...MLD Tab 134 100G RS FEC Ethernet 400G RS FEC Ethernet MPA_e_manual_D07 00 129P_RevA00...
Page 255: ...Protocol Tabs 255 MPA_e_manual_D07 00 129P_RevA00...
Page 256: ...OTN Tab 256 MPA_e_manual_D07 00 129P_RevA00...
Page 748: ...MPA_e_manual_D07 00 129P_RevA00...
Page 796: ...MPA_e_manual_D07 00 129P_RevA00...