F
u
nct
ion
d
ia
gr
am
s
PR
OFIdriv
e
2-
79
2
© Siemens AG
2012 All Rights Reserved
SINAMICS
S110
List Manual (LH7
), 06/201
2, 6SL3097-
4AP
1
0-0BP3
Fi
g. 2
-3
5
245
4
–
ZSW2
status
word
intercon
nection
(p2
038
=
0
)
- 2454 -
Function diagram
8
7
6
5
4
3
2
1
fp_2454_98_eng.vsd
DO: SERVO
SINAMICS S110
25.01.10 V04.04.00
PROFIdrive - ZSW2 status word interconnection (p2038 = 0)
<2>
<1> Used in telegrams 2, 3, 4, 7, 110, 111.
<2> These signals are automatically interconnected for clock-cycle synchronous operation.
[Function diagram]
signal source
Interconnection
parameters
Signal
Meaning
-
-
-
p2081[7] = r0896.0
p2081[8] = r1406.8
-
p2081[11] = r0835.0
Implicitly interconnected
p2081[0] = r0051.0
-
ZSW2.0
ZSW2.1
ZSW2.2
ZSW2.3
ZSW2.4
ZSW2.5
ZSW2.6
ZSW2.8
ZSW2.9
ZSW2.11
ZSW2.12
ZSW2.13
ZSW2.14
ZSW2.15
ZSW2.7
ZSW2.10
1 = Drive data set DDS effective, bit 0
Reserved
Reserved
Reserved
Reserved
1 = Parking axis active
1 = Traverse to fixed endstop
Reserved
1 = Motor data set changeover active
Slave sign-of-life bit 0
Slave sign-of-life bit 1
Slave sign-of-life bit 3
Slave sign-of-life bit 2
-
-
-
-
-
-
-
-
-
-
-
-
-
[Function diagram]
internal status word
-
-
-
-
-
-
[2520]
-
-
-
-
[8565]
-
Signal sources for ZSW2 in Interface Mode SINAMICS (p2038 = 0)
<1>
-
-
-
-
-
-
-
-
-
-
-
-
-
Inverted
Refer to [1020.7]
PROFIdrive sampling time
1 = Alarm class bit 1
1 = Alarm class bit 0
p2081[5] = r2139.11
p2081[6] = r2139.12
1 = Pulses enabled
p2082[13] = r0899.11