Function diagram
8
7
6
5
4
3
2
1
DO: SERVO
SINAMICS S110
17.10.08 V04.04.00
Servo control - Motoring/regenerating torque limit
fp_5620_98_eng.vsd
+
+
+
+
<0
<0
-1
-1
(1524)
p1528[C]
(1520)
p1522[C]
p1520[D]
<1>
(1525)
p1529[C]
(1521)
p1523[C]
p1521[D]
<1>
–
+
+
–
Reverse,
generating
Forward,
generating
Forward,
motoring
Reverse,
motoring
2
1
M
n
3
4
M
n
1
3
M
n
2
4
M
n
3
M
n
4
M
n
2
M
n
2
1
M
n
4
3
M
1
n
1000.00 μs
<2>
<2>
0
1
0
1
0
0
(1)
M_lim var/fixS_src
p1551[C]
e.g.
0 = Quick stop activated
(OFF3)
r0899.5
M_max low/gen scal
-2000.0...2000.0 [%]
p1525[D] (100.0)
p1525[D]
p1524[D]
M_max up/mot scal
-2000.0...2000.0 [%]
p1524 (100.0)
0
1
1400.13
<3>
<3>
The 4 quadrants
M_offset
M_offset
M_max offset
-100 000.00...100 000.00 [Nmp]
1532[D] (0.00)
[5640.1]
[5640.1]
<1> For p1400.4 = 1, the first torque limit applies for motoring operation and the other for regenerative operation, independently of the sign of the torque
and the speed (compatible with SIMODRIVE).
"Normal case": If neither dynamic limits nor offsets are required, the torque limit when motoring is entered via p1520. The torque limit when
regenerating is entered via p1521 (as a negative value).
For the manufacturer-specific PROFIdrive telegrams 102 und 103, r1543 is entered here [5610.4].
<2>
<3> With p1400.13 = 0, the following applies: if n_act < p1546, the motor limit is effective.
With p1400.13 = 1, the following applies: if n_set = 0, the regenerative limit is effective.
Regenerating torque limit
Motoring torque limit
r0063
n_act smooth
[4710.6]
r1438
n_ctrl n_set
[5030.8]
e.g. from MOMRED
e.g. from MOMRED
M_max upper/mot
-100 000.00...100 000.00 [Nm]
p1520 (100.00)
M_max lower/regen
-100 000.00...100 000.00 [Nm]
p1521[D] (0.00)
M_max 2
M_min 2
r1527
M_max low w/o offs
r1526
M_max up w/o offs