
List of parameters
Parameter
1-367
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the "fractional" dead time to emulate the timing behavior of the speed control loop.
The selected multiplier refers to the position controller clock cycle (deadtime= p2535 * p0115[4]).
Dependency:
Refer to: p2536
Notice:
When speed pre-control is active (p2534 > 0 %), the following applies:
In addition to the set dead time (p2535), internally two position controller clock cycles are effective.
When speed pre-control is inactive (p2534 = 0 %), the following applies:
No dead time is effective (p2535 and internal).
Note:
Together with p2536, the timing behavior of the closed-loop control loop can be emulated.
Description:
Sets a PT1 filter to emulate the timing behavior of the closed-speed control loop.
Dependency:
Refer to: p2535
Notice:
When speed pre-control is inactive (p2534 = 0 %), the following applies:
If a PT1 filter has been set, it is not effective.
Note:
Together with p2535, the timing behavior of the closed-loop control loop can be emulated.
Description:
Sets the signal source for the adaptation of the proportional gain of the position controller.
Dependency:
Refer to: p2538
Description:
Sets the proportional gain (P gain, position loop gain, Kv factor) of the position controller.
Dependency:
Refer to: p2537, p2539, p2555, r2557, r2558
p2535[0...n]
LR speed pre-control balancing filter dead time / n_prectrFlt t_dead
SERVO_S110-CAN
(Pos ctrl),
SERVO_S110-DP
(Pos ctrl),
SERVO_S110-PN
(Pos ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
4015
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 2.00
0.00
p2536[0...n]
LR speed pre-control, symmetrizing filter PT1 / n_prectrl filt PT1
SERVO_S110-CAN
(Pos ctrl),
SERVO_S110-DP
(Pos ctrl),
SERVO_S110-PN
(Pos ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
4015
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
100.00 [ms]
0.00 [ms]
p2537
CI: LR position controller adaptation / Adaptation
SERVO_S110-CAN
(Pos ctrl),
SERVO_S110-DP
(Pos ctrl),
SERVO_S110-PN
(Pos ctrl)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
4015
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
1
p2538[0...n]
LR proportional gain / Kp
SERVO_S110-CAN
(Pos ctrl),
SERVO_S110-DP
(Pos ctrl),
SERVO_S110-PN
(Pos ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
4015
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 [1000/min]
300.000 [1000/min]
1.000 [1000/min]