List of parameters
Parameter
1-109
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency:
Refer to: p0440, p0441, p0442, p0443, p0445, r0460, r0461, r0462, r0463, r0464
Refer to: F07414
Note:
A value of zero is displayed if an encoder is not present.
Description:
Serial number part 5 of the encoder for the commissioning.
Dependency:
Refer to: p0440, p0441, p0442, p0443, p0444, r0460, r0461, r0462, r0463, r0464
Refer to: F07414
Note:
A value of zero is displayed if an encoder is not present.
Description:
Sets the number of bits before the absolute value in the SSI protocol.
Caution:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
For example, error bit, alarm bit or parity bit can be positioned at these bits.
Description:
Sets the number of bits for the absolute value in the SSI protocol.
Caution:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Description:
Sets the number of bits after the absolute value in the SSI protocol.
Caution:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
For example, error bit, alarm bit or parity bit can be positioned at these bits.
p0445[0...n]
Encoder commissioning serial number part 5 / Enc comm ser_no 5
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(4)
Calculated:
CALC_MOD_ALL
Access level:
4
Data type:
Unsigned32
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p0446[0...n]
Encoder SSI number of bits before the absolute value / Enc SSI bit before
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 65535
0
p0447[0...n]
Encoder SSI number of bits absolute value / Enc SSI bit val
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 65535
25
p0448[0...n]
Encoder SSI number of bits after the absolute value / Enc SSI bit after
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 65535
0