
List of parameters
Parameter
1-395
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the signal source to select the traversing block, bit 4.
Dependency:
Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2625, p2626, p2627, p2628, p2630
Description:
Sets the signal source to select the traversing block, bit 5.
Dependency:
Binector inputs p2625, p2626, p2627, p2628, p2629 and p2630 are used to select one of the maximum of 64 tra-
versing blocks.
Refer to: p2625, p2626, p2627, p2628, p2629
Description:
Sets the signal source for "activating traversing task".
BI: p2631 = 0/1 signal
The traversing task, selected using BI: p2625 ... p2630, is started.
Dependency:
Refer to: p2625, p2626, p2627, p2628, p2629, p2630, p2640, p2641
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
To start a traversing block, the axis must be referenced (r2684.11 = 1).
The status signal r2684.12 = 0/1 signal is used for acknowledgement.
A traversing task can be influenced using the following signals:
- intermediate stop via BI: p2640.
- reject traversing task via BI: p2641.
p2629
BI: EPOS traversing block selection, bit 4 / Trav_blk sel bit 4
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
3616, 3640
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2630
BI: EPOS traversing block selection, bit 5 / Trav_blk sel bit 5
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
3616, 3640
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2631
BI: EPOS activate traversing task (0 -> 1) / Trav_task act
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
3616, 3625
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0