Parameter
List of parameters
1-146
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Displays the access authority at the digital outputs.
Bit = 1:
The control has access authority to the digital output via PROFIBUS or direct access.
Bit = 0:
The drive has access authority to the digital output or the digital input/output is not set as digital output or is not
available.
Dependency:
Refer to: p0728, p0738, p0739, p0740, p0741, r0747, p0748
Note:
The DI/DO must be connected as output (p0728).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for terminal DI/DO 8 (X132.1).
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.8 = 1).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for terminal DI/DO 9 (X132.2).
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.9 = 1).
DI/DO: Bidirectional Digital Input/Output
r0729
CU digital outputs access authority / CU DO acc_auth
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2030, 2031
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
08
DI/DO 8 (X132.1)
High
Low
-
09
DI/DO 9 (X132.2)
High
Low
-
10
DI/DO 10 (X132.3)
High
Low
-
11
DI/DO 11 (X132.4)
High
Low
-
16
DO 16 (X131.5)
High
Low
-
p0738
BI: CU, signal source for terminal DI/DO 8 / CU S_src DI/DO 8
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
1510, 2030
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p0739
BI: CU, signal source for terminal DI/DO 9 / CU S_src DI/DO 9
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
1510, 2030,
2130, 2497, 2498
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0