List of parameters
Parameter
1-417
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the configuration for position tracking of a load gear.
Note:
For the following events, the non-volatile, saved position values are automatically reset:
- when an encoder replacement has been identified.
- when changing the configuration of the Encoder Data Set (EDS).
- when adjusting the absolute encoder again
Description:
Sets the number of rotations that can be resolved for a rotary absolute encoder with activated position tracking of
the load gear.
Dependency:
This parameter is only of significance for an absolute encoder (p0404.1 = 1) with activated position tracking of the
load gear (p2720.0 = 1).
Note:
The resolution that is set must be able to be represented using r2723.
For rotary axes/modulo axes, the following applies:
This parameter is pre-set with p0421 and can be changed.
For linear axes, the following applies:
This parameter is pre-assigned with p0421, expanded by 6 bits for multiturn information (maximum number of over-
flows) and cannot be changed.
Description:
Sets a tolerance window for position tracking.
After the system is powered up, the difference between the saved position and the actual position is determined,
and depending on this, the following is initiated:
Difference within the tolerance window --> The position is reproduced as a result of the encoder actual value.
Difference outside the tolerance window --> An appropriate message is output.
Dependency:
Refer to: F07449
Caution:
Rotation, e.g. through a complete encoder range is not detected.
p2720[0...n]
Load gear configuration / Load gear config
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(1, 4)
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Load gear, activate position tracking
Yes
No
-
01
Axis type
Linear axis
Rotary axis
-
02
Load gear, reset position
Yes
No
-
p2721[0...n]
Load gear, rotary absolute gearbox, revolutions, virtual / Abs rot rev
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(1, 4)
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 4194303
0
p2722[0...n]
Load gear, position tracking tolerance window / Pos track tol
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(1, 4)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 4294967300.00