F
u
nct
ion
d
ia
gr
am
s
Exp
lan
ations
on
the
fu
nctio
n
dia
g
ra
ms
2-
75
4
© Siemens AG
2012 All Rights Reserved
SINAMICS
S110
List Manual (LH7
), 06/201
2, 6SL3097-
4AP
1
0-0BP3
Fi
g. 2
-1
102
0
–
Exp
lana
tion
of the
symbol
s (Part
1)
- 1020 -
Function diagram
8
7
6
5
4
3
2
1
fp_1020_98_eng.vsd
DO: All objects
SINAMICS S110
28.05.10 V04.04.00
Explanations for the function diagrams - Explanation of the symbols (Part 1)
Data sets
Connectors/binectors
Parameter name
rxxxx
rxxxx
Connector/binector output CO/BO
Symbol
Meaning
Parameter belongs to the
Command Data Set (CDS).
Parameter belongs to the
Drive Data Set (DDS).
Parameter belongs to the
Encoder Data Set (EDS).
Parameter belongs to the
Motor Data Set (MDS).
Parameter belongs to the
Power unit Data Set (PDS).
Parameter name
[Unit]
rxxxx[y] or
rxxxx[y...z] or
rxxxx[y].ww or
rxxxx.ww
pxxxx[y] or
pxxxx[y...z] or
pxxxx[y].ww or
pxxxx.ww
from ... to
(xxxx[y].ww)
(Def)
(Def.w)
Information on parameters, binectors, connectors
Parameter name (up to 18 characters)
[dimension unit]
"r" = monitoring parameter. These parameters are read-only
"xxxx" stands for the parameter number
"[y]" specifies the valid index, "[y...z]" specifies the applicable index range
".ww" specifies the bit number (e.g. 0...15).
"p" = setting parameter. These parameters can be changed.
"xxxx" stands for the parameter number,
"[y]" specifies the applicable index, "[y...z]" specifies the applicable index range
".ww" specifies the bit number (e.g. 0...15).
Value range.
Parameter number (xxxx) with Index number [y] and bit number .ww.
Factory setting.
Factory setting with bit number as prefix.
Diagram references for setting parameters that occur a multiple number of times.
[Function diagram number, signal path]
Cross references between diagrams
[aaaa.b]
Text = Unique signal designation
aaaa = Signal goes to target diagram aaa
b
= Signal goes to signal path b
[cccc.d]
Text
Text
Text = Unique signal designation
cccc = Signal comes from source diagram cccc
d
= Signal comes from signal path d
Meaning
Symbol
Symbol
Meaning
Sampling times
Fixed time slice.
Symbol
Meaning
Meaning
Symbol
According to presetting in p2048. (In
synchronous mode, bus clock is valid.)
A static state is displayed here. The
sampling time data is not relevant.
There is no fixed sampling time for this
function. The processing takes place in
background. The cycle time depends on
the computational load of the control unit.
Signal path
The function diagrams are sub-divided into signal
paths 1...8 in order to facilitate orientation.
Cross references for control bits
Symbol
[aaaa.b]
pxxxx
pxxxx= Original parameter of signal
aaaa = Signal comes from source diagram aaaa
b
= Signal comes from signal path b
Meaning
[aaaa.b]
pxxxx[P]
pxxxx[M]
pxxxx[E]
pxxxx[D]
pxxxx[C]
PROFIdrive sampling time
Refer to [1020.7]
Background
Not relevant
Refer to [1020.7]
ZZZ.ZZ μs
CAN bus sampling time
According to presetting in p2048.
Parameter
Monitoring parameter
(parameter may appear .
Monitoring parameter
with index.
Setting parameter
(if the parameter appears
a multiple number of times,
then diagram references
are specified).
Setting parameter with
index (if the parameter
appears a multiple number
of times, then diagram
references are specified).
Meaning
Symbol
Parameter name [Unit]
rxxxx [x...y]
Parameter name [Unit]
Index name
rxxxx[x]
[aaaa.b]
Parameter name
from ... to [Unit]
pxxxx[y...z] (Def)
[aaaa.b]
Parameter name
Index name
from ... to [Unit]
pxxxx[y] (Def)
name
(xxxx [y])
pxxxx[y...z]
name
(xxxx [x])
pxxxx[y]
rxxxx[y...z]
name [unit]
rxxxx[y]
name [unit]
(Def)
Name
pxxxx[y...z]
(Def)
Name
pxxxx[y]
Name
rxxxx
name
rxxxx.y
(Def)
Name
pxxxx
Name
(xxxx)
pxxxx
Binektoreingang BI
Werkseinstellung (Def).
Connectors
Connector input CI with index
range [y...z]
Connector input CI.
Connector output CO with [dimension
unit] and index range [y...z].
Connector output CO
[dimension unit] and with index [y]
Meaning
Symbol
Connector input CI with index [y]
Binector output BO with
bit y.
Binector output BO.
Binector input BI with
index [y] and factory
setting (Def).
Binector input BI with
index range [y...z] and
factory setting (Def).
Binectors
Symbol
Meaning