List of parameters
Parameter
1-447
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency:
Refer to: p4681, p4682, p4683, p4684
Note:
The display can only be reset to zero.
Description:
Displays the encoder status according to PROFIdrive for a squarewave encoder.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: A31422
Note:
After alarm A3x422 is output, this parameter is set for 100 ms.
Description:
Sets the component number for the SMI/DQI for which motor and/or encoder data should be saved, deleted or
downloaded.
Dependency:
Refer to: p4691, p4692, p4693
Note:
DQI: DRIVE-CLiQ Sensor Integrated
SMI: SINAMICS Sensor Module Integrated
Description:
Setting to save/download the data for the Sensor Module Integrated (SMI) specified in p4690.
Procedure:
p4690 = set component number
p4691 = 1, 2, 3, 30 set the required procedure (save/download/delete)
p4691 = 9, 10, 36 automatic on successful completion of the procedure
p4691 = 11... 22, 37, 38 --> error values if the procedure could not be executed
Value:
0:
Inactive
1:
Save SMI data
2:
Download SMI data
3:
Download SMI data from memory card
9:
SMI data downloaded and POWER ON required for component
10:
SMI data backup complete
11:
SMI data backup for selected component not found
12:
Selected component not available or not connected
13:
Insufficient memory space for backup
14:
Format of saved data is incompatible
15:
Transfer fault during data download
16:
Transfer fault during data backup
r4689[0...2]
CO: Squarewave encoder, diagnostics / Sq-wave enc diag
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p4690
SMI spare part component number / SMI comp_no
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 399
0
p4691
SMI spare part save/download data / Save/DL SMI data
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 38
0