Parameter
List of parameters
1-248
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the signal source to set the integrator setting value (p1478).
Dependency:
Refer to: p1478
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
For the interface mode "SIMODRIVE 611 universal" (p2038 = 1), p1477 and p1478 are used for the signal STW2.6
(integrator inhibit, speed controller).
Description:
Sets the signal source for the integrator setting value for the velocity controller.
The signal to set this integrator setting value is interconnected via p1477.
Dependency:
Refer to: p1477
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
For the interface mode "SIMODRIVE 611 universal" (p2038 = 1), p1477 and p1478 are used for the signal STW2.6
(integrator inhibit, speed controller).
Description:
Displays the torque setpoint at the output of the PI speed controller.
Description:
Displays the torque setpoint at the output of the P speed controller.
p1477[0...n]
BI: Speed controller set integrator value / n_ctrl integ set
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2520, 5040,
5042, 5210, 6040
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p1478[0...n]
CI: Speed controller integrator setting value / n_ctr integ_setVal
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
5040, 5042,
5210
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
p2003
Expert list:
1
Min Max
Factory
setting
- -
0
r1480
CO: Speed controller PI torque output / n_ctrl PI-M_output
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
1590, 5040,
5042, 5060, 5210, 6060
P-Group:
Closed-loop control
Units group:
7_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
p2003
Expert list:
1
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
r1481
CO: Speed controller P torque output / n_ctrl P-M_output
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
5040, 5042,
5210, 6040
P-Group:
Closed-loop control
Units group:
7_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
p2003
Expert list:
1
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]