List of parameters
Parameter
1-475
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the upper limit for the function generator.
Dependency:
For p4810 = 2 the limit only applies to the current setpoint, but not the speed setpoint (offset).
Description:
Sets the time slice cycle in which the function generator is called.
Description:
Sets the scaling for the amplitude of the signal waveforms for all output channels.
The value can be changed while the function generator is running.
Description:
Sets the scaling for the amplitude of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Description:
Sets the scaling for the offset of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
p4829
Function generator upper limit / FG upper limit
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0.00 [%]
10000.00 [%]
100.00 [%]
p4830
Function generator time slice cycle / FG time slice
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0.03125 [ms]
2.00000 [ms]
0.12500 [ms]
p4831
Function generator amplitude scaling / FG amplitude scal
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0.00000 [%]
200.00000 [%]
100.00000 [%]
p4832[0...2]
Function generator amplitude scaling / FG amplitude scal
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
-340.28235E36 [%]
340.28235E36 [%]
100.00000 [%]
p4833[0...2]
Function generator offset scaling / FG offset scal
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
-340.28235E36 [%]
340.28235E36 [%]
100.00000 [%]