Safety Integrat
ed
Fu
nction dia
g
ra
ms
2-
85
1
© Siemens AG 2
012 All Rights Reserved
SINAMICS
S110 List Manual (L
H7)
, 06/
2012
, 6SL3097-
4AP10-0BP3
Fi
g.
2
-9
0
286
0 – Exten
ded F
unction
s, SSM (Safe Speed
Mon
itor)
- 2860 -
Function diagram
8
7
6
5
4
3
2
1
fp_2860_98_eng.vsd
DO: SERVO
SINAMICS S110
Safety Integrated - Extended Functions, SSM (Safe Speed Monitor)
p9500 (12.00 ms)
27.04.11 V04.04.00
0
1
Enable SSM hysteresis filter
p9501.16 (0000 bin)
Enable SSM hysteresis filter
p9301.16 (0000 bin)
SI Mtn SSM hyst P1
0.0010...500.0000 [1/min]
p9547 (10.0000)
SI Mtn SSM hyst P2
0.0010...500.0000 [1/min]
p9347 (10.0000)
Si Mtn SSM v_lim P1
0.00...1000 000.00 [1/min]
p9546 (20.00)
SI Mtn SSM v_lim P2
0.00...1000 000.00 [1/min]
p9346 (20.00)
0
1
0
1
0.00...100.00 [ms]
p9545 (0.00)
0.00...100 000.00 [μs]
p9345 (0.00)
Load-side v_act
r9714[0]
SSM (speed below limit value)
r9722.15
r9722
SI Mtn integ stat
Safe speed
recording
[2840.5]