
Parameter
List of parameters
1-150
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the scaling characteristic for the analog input.
The scaling characteristic for the analog input is defined using 2 points.
This parameter specifies the x coordinate (input voltage in V) of the 2nd value pair of the characteristic.
Note:
The parameters for the characteristic do not have a limiting effect.
Description:
Sets the scaling characteristic for the analog input.
The scaling characteristic for the analog input is defined using 2 points.
This parameter specifies the y coordinate (percentage) of the 2nd value pair of the characteristic.
Note:
The parameters for the characteristic do not have a limiting effect.
Description:
Sets the offset for the analog input.
The offset is added to the input signal before the scaling characteristic.
Description:
Activates the absolute value generation of the analog input signal.
Value:
0:
No absolute value generation
1:
Absolute value generation switched in
p0759
CU analog input characteristic value x2 / CU AI char x2
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2040
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-11.000 [V]
11.000 [V]
10.000 [V]
p0760
CU analog input characteristic value y2 / CU AI char y2
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2040
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-1000.00 [%]
1000.00 [%]
100.00 [%]
p0763
CU analog input offset / CU AI offset
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2040
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-20.000 [V]
20.000 [V]
0.000 [V]
p0766
CU analog input activate absolute value generation / CU AI absVal act
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
2040
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0