Parameter
List of parameters
1-722
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
3:
Run-time group 3
4:
Run-time group 4
5:
Run-time group 5
6:
Run-time group 6
7:
Run-time group 7
8:
Run-time group 8
9:
Run-time group 9
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance PT1 1 within the run-time group set in p20254.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of input quantity X and of setting value SV of instance INT 0 of the integrator.
Index:
[0] = Input X
[1] = Setting value SV
Description:
Sets the upper limit value LU of instance INT 0 of the integrator.
p20255
PT1 1 run sequence / PT1 1 RunSeq
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
7262
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 32000
680
p20256[0...1]
CI: INT 0 inputs / INT 0 inputs
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
7264
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
0
p20257
INT 0 upper limit value LU / INT 0 upper lim LU
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
7264
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-340.28235E36 340.28235E36
0.0000