List of parameters
Parameter
1-321
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency:
Selects the faults and sets the required acknowledge mode realized under the same index
Refer to: p2126
Notice:
It is not possible to re-parameterize the acknowledge mode of a fault in the following cases:
- if there is no existing fault number.
- the message type is not "fault" (F).
- when a fault is present.
Note:
The acknowledge mode can only be changed for faults with the appropriate identification.
Example:
F12345 and acknowledge mode = IMMEDIATE (POWER ON)
--> The acknowledge mode can be changed from IMMEDIATELY to POWER ON.
Description:
Selects faults or alarms which can be used as trigger.
Dependency:
Refer to: r2129
Description:
Trigger signal for the selected faults and alarms
Dependency:
If one of the faults or alarms selected in p2128[n] occurs, then the particular bit of this binector output is set.
Refer to: p2128
Note:
CO: r2129 = 0 --> None of the selected messages has occurred.
CO: r2129 > 0 --> At least one of the selected messages has occurred.
p2128[0...15]
Selecting fault/alarm code for trigger / Message trigger
All objects
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1750, 8070
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 65535
0
r2129.0...15
CO/BO: Trigger word for faults and alarms / Trigger word
All objects
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1530, 8070
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Trigger signal p2128[0]
ON
OFF
-
01
Trigger signal p2128[1]
ON
OFF
-
02
Trigger signal p2128[2]
ON
OFF
-
03
Trigger signal p2128[3]
ON
OFF
-
04
Trigger signal p2128[4]
ON
OFF
-
05
Trigger signal p2128[5]
ON
OFF
-
06
Trigger signal p2128[6]
ON
OFF
-
07
Trigger signal p2128[7]
ON
OFF
-
08
Trigger signal p2128[8]
ON
OFF
-
09
Trigger signal p2128[9]
ON
OFF
-
10
Trigger signal p2128[10]
ON
OFF
-
11
Trigger signal p2128[11]
ON
OFF
-
12
Trigger signal p2128[12]
ON
OFF
-
13
Trigger signal p2128[13]
ON
OFF
-
14
Trigger signal p2128[14]
ON
OFF
-
15
Trigger signal p2128[15]
ON
OFF
-