List of parameters
Parameter
1-555
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency:
Refer to: p9501
Refer to: F01686
Note:
The "Safe Cam" function (SCA) can either be enabled using p9501 or p9503.
SCA: Safe Cam / SN: Safe software cam
Description:
Sets the modulo range of the safe position actual value in degrees for the function "Safe Cam" (SCA) for rotary
axes.
Dependency:
Refer to: p9536, p9537
Note:
SCA: Safe Cam / SN: Safe software cam
Description:
Sets the function specification for the safe motion monitoring.
Value:
0:
Safety with encoder
1:
Safety without encoder
3:
Safety without encoder with accel_monitoring/delay time
Dependency:
Refer to: C01711
10
Enable SCA11 (SN11)
Enable
Inhibit
-
11
Enable SCA12 (SN12)
Enable
Inhibit
-
12
Enable SCA13 (SN13)
Enable
Inhibit
-
13
Enable SCA14 (SN14)
Enable
Inhibit
-
14
Enable SCA15 (SN15)
Enable
Inhibit
-
15
Enable SCA16 (SN16)
Enable
Inhibit
-
16
Enable ESCA17 (SN17)
Enable
Inhibit
-
17
Enable SCA18 (SN18)
Enable
Inhibit
-
18
Enable SCA19 (SN19)
Enable
Inhibit
-
19
Enable SCA20 (SN20)
Enable
Inhibit
-
20
Enable SCA21 (SN21)
Enable
Inhibit
-
21
Enable SCA22 (SN22)
Enable
Inhibit
-
22
Enable SCA23 (SN23)
Enable
Inhibit
-
23
Enable SCA24 (SN24)
Enable
Inhibit
-
24
Enable SCA25 (SN25)
Enable
Inhibit
-
25
Enable SCA26 (SN26)
Enable
Inhibit
-
26
Enable SCA27 (SN27)
Enable
Inhibit
-
27
Enable SCA28 (SN28)
Enable
Inhibit
-
28
Enable SCA29 (SN29)
Enable
Inhibit
-
29
Enable SCA30 (SN30)
Enable
Inhibit
-
p9505
SI Motion SCA (SN) modulo value (Control Unit) / SI Mtn SCA modulo
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [°]
737280 [°]
0 [°]
p9506
SI Motion function specification (processor 1) / SI Mtn fct_spc P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 3
0