In
te
rn
al co
nt
ro
l/sta
tu
s wo
rd
s
Fu
nction dia
g
ra
ms
2-
81
9
© Siemens AG 2
012 All Rights Reserved
SINAMICS
S110 List Manual (L
H7)
, 06/
2012
, 6SL3097-
4AP10-0BP3
Fi
g.
2
-6
1
252
6 – Status word, closed
-loop
con
tro
l
- 2526 -
Function diagram
8
7
6
5
4
3
2
1
fp_2526_98_eng.vsd
DO: SERVO
SINAMICS S110
30.10.08 V04.04.00
Internal control/status words - Status word, closed-loop control
1
2
4
Reserved
Meaning
1 = De-magnetization completed
Reserved
1 = Magnetization completed
Reserved
0
Bit No.
7
Status word closed-loop control
8
9
11
1 = Field weakening active
Reserved
Reserved
1 = Vdc_max controller active
14
1 = Vdc_min controller active
15
r0056
ZSW closed-loop control
r0056.14
r0056.15
r0056.1
r0056.4
r0056.8
3
Reserved
5
Reserved
6
Reserved
12
Reserved
13
Reserved
10
Reserved
Refer to [1020.7]
250 s
[2701.1][2707.1]
[5650.8]
[5650.8]
[6722.6][6725.6]
[6722.3][6725.4]