
List of parameters
Parameter
1-147
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the signal source for terminal DI/DO 10 (X132.3).
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.10 = 1).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for terminal DI/DO 11 (X132.4).
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.11 = 1).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for terminal DO 16.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Terminal DO 16 is used for Safety Extended Functions if these have been enabled using p9601 and are not con-
trolled via PROFIsafe, and provided that a signal source has been set for the F-DO using p10042.
The signal source entered in p0746 is then no longer output at terminal DO 16.
Note:
DO: Digital Output
Description:
Displays the status of digital outputs.
p0740
BI: CU, signal source for terminal DI/DO 10 / CU S_src DI/DO 10
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
1510, 2031,
2497, 2498
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p0741
BI: CU, signal source for terminal DI/DO 11 / CU S_src DI/DO 11
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
1510, 2031,
2497, 2498
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p0746
BI: CU signal source for terminal DO 16 / CU S_src DO 16
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
1510, 2032
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
r0747
CU, digital outputs status / CU DO status
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2130, 2131,
2132, 2133
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-