CU30
5
inpu
t/o
u
tput te
rm
inals
Fu
nction dia
g
ra
ms
2-
76
9
© Siemens AG 2
012 All Rights Reserved
SINAMICS
S110 List Manual (L
H7)
, 06/
2012
, 6SL3097-
4AP10-0BP3
Fi
g. 2
-1
4
202
0
–
Digital
inputs, e
lec
trically isol
ated (DI
0 to DI 3)
- 2020 -
Function diagram
8
7
6
5
4
3
2
1
fp_2020_98_eng.vsd
DO: CU_S110
SINAMICS S110
01.06.10 V04.04.00
CU305 input/output terminals - Digital inputs, electrically isolated (DI 0 ... DI 3)
X133.1
X133.2
X133.3
X133.4
1 = Simulation on
p0795.0
r0723.0
r0722.0
p0795.1
r0723.1
r0722.1
p0795.2
r0723.2
r0722.2
p0795.3
r0723.3
r0722.3
r0722
r0723
X133.5
M2
M2
<1> When using the electrical isolation, omit the
terminal jumper and connect the load power supply
shown as a dashed line.
<1>
X133.6
1
0
1
0
1
0
1
0
1
1
1
1
24 V
DI 3
DI 2
DI 1
DI 0
DI 0 … DI 3
inverted
DI 0 … DI 3
r0721.0
r0721.1
r0721.2
r0721.3
<1>
p0796.3
p0796.2
p0796.1
p0796.0
<1>
4000.00 s
+
24 V
5 V
<1>
+24 V
X124.M
X124.+
M
X124.M
M
24 V DC to the next device
X124.+
+