List of parameters
Parameter
1-415
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
All voltages specified as relative value are referred to this reference quantity. The reference quantity in this param-
eter corresponds to 100% or 4000 hex or 4000 0000 hex.
This parameter has the unit Vrms.
Dependency:
Refer to: p2001
Note:
This parameter provides the numerical value of the reference quantity p2001 as a connector output for interconnec-
tion with Drive Control Chart (DCC). The numerical value can be adopted unchanged from this connector output in
DCC.
Description:
Connector output of the reference quantity for currents p2002.
All currents specified as relative value are referred to this reference quantity. The reference quantity in this parame-
ter corresponds to 100% or 4000 hex or 4000 0000 hex.
This parameter has the unit Arms.
Dependency:
Refer to: p2002
Note:
This parameter provides the numerical value of the reference quantity p2002 as a connector output for interconnec-
tion with Drive Control Chart (DCC). The numerical value can be adopted unchanged from this connector output in
DCC.
Description:
Connector output of the reference quantity p2003 for torque (r0108.12 = 0) or force (r0108.12 = 1).
All torques specified as relative values (r0108.12 = 0) or forces (r0108.12 = 1) are referred to this reference quan-
tity. The reference quantity in this parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
The unit of this parameter is the same as the unit selected for p2003.
Dependency:
p0505, r0108.12
Refer to: p2003
Note:
This parameter provides the numerical value of the reference quantity p2003 in the currently selected unit as a con-
nector output for interconnection with Drive Control Chart (DCC). The numerical value can be adopted unchanged
from this connector output in DCC.
Description:
Connector output of the reference quantity for powers p2004.
All power ratings specified as relative value are referred to this reference quantity. The reference quantity in this
parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
The unit of this parameter is the same as the unit selected for p2004.
Dependency:
This value is calculated as voltage x current for the infeed and as torque x speed for closed-loop controls.
Refer to: r2004
r2702
CO: Reference current / Reference current
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r2703
CO: Reference torque / Reference torque
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r2704
CO: Reference power / Reference power
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-