Parameter
List of parameters
1-670
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Display parameter for the inverted output of instance NOT 2 of the inverter.
Description:
Setting parameter for the run-time group in which the instance NOT 2 of the inverter is to be called.
Value:
0:
Run-time group 0
1:
Run-time group 1
2:
Run-time group 2
3:
Run-time group 3
4:
Run-time group 4
5:
Run-time group 5
6:
Run-time group 6
7:
Run-time group 7
8:
Run-time group 8
9:
Run-time group 9
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance NOT 2 within the run-time group set in p20088.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
r20087
BO: NOT 2 inverted output / NOT 2 inv output
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
7216
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p20088
NOT 2 run-time group / NOT 2 RTG
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
7216
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 9999
9999
p20089
NOT 2 run sequence / NOT 2 RunSeq
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
7216
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 32000
180