List of parameters
Parameter
1-31
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Note:
Procedure:
1.
The parameter number to be displayed should be set in index 0. Only the monitoring parameters (read-only param-
eters) can be set that actually exist for the actual drive object.
If the set parameter number is not indexed, or if there is an index in index 1 that lies outside the valid range of the
set parameter, then index 1 is automatically set to 0.
2.
The index that belongs to the parameter set in index 0 should be set in index 1. The permissible changes in index 1
always depend on the parameter number set in index 0.
Description:
Sets the mode of the operating display for the Basic Operator Panel (BOP) in the operating states "ready for opera-
tion" and "operation".
Value:
4:
p0005
Dependency:
Refer to: p0005
Note:
Mode 0 ... 3 can only be selected if also r0020, r0021 are available on the drive object.
Mode 4 is available for all drive objects.
Description:
Sets the mode of the operating display for the Basic Operator Panel (BOP) in the operating states "ready for opera-
tion" and "operation".
Value:
0:
Operation --> r0021, otherwise r0020 <--> r0021
1:
Operation --> r0021, otherwise r0020
2:
Operation --> p0005, otherwise p0005 <--> r0020
3:
Operation --> r0002, otherwise r0002 <--> r0020
4:
p0005
Dependency:
Refer to: p0005
Note:
Mode 0 ... 3 can only be selected if also r0020, r0021 are available on the drive object.
Mode 4 is available for all drive objects.
Description:
Sets the delay time until the background lighting of the Basic Operator Panel (BOP) is switched off.
If no keys are actuated, then the background lighting automatically switches itself off after this time has expired.
Note:
p0007 = 0: Background lighting is always switched on (factory setting).
p0006
BOP operating display mode / BOP op_ disp mode
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
4 4
4
p0006
BOP operating display mode / BOP op_ disp mode
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 4
4
p0007
BOP background lighting / BOP lighting
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [s]
2000 [s]
0 [s]