Parameter
List of parameters
1-154
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets an additional offset for the test sockets.
Index:
[0] = T0
[1] = T1
[2] = Reserved
Description:
Sets the limit for a signal to be output via test sockets.
Value:
0:
Limiting off
1:
Limiting on
Index:
[0] = T0
[1] = T1
[2] = Reserved
Note:
Limiting on:
If signals are output outside the permissible measuring range, the signal is limited to 4.98 V or to 0 V.
Limiting off:
If signals are output outside the permissible measuring range, this causes signal overflow. In the case of signal
overflow, the signal jumps from 0 V to 4.98 V or from 4.98 V to 0 V.
Description:
Displays the scaling of the signal to be output. A change in the output voltage by 1 volt corresponds to the value in
this parameter. The units are determined by the interconnected test signal.
Index:
[0] = T0
[1] = T1
[2] = Reserved
Dependency:
Refer to: p0771, r0772, r0774, p0777, p0778, p0779, p0780, p0783, p0784
Note:
Example:
r0786[0] = 1500.0 and the measuring signal is r0063 (CO: Actual speed smoothed [rpm]).
A change of 1 V at the output of test socket T0 corresponds to 1500.0 [rpm].
p0783[0...2]
Test sockets offset / Test skt offset
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
8134
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-4.60 [V]
4.60 [V]
0.00 [V]
p0784[0...2]
Test socket limit on/off / TestSktLim on/off
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dynamic index:
-
Func. diagram:
8134
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
r0786[0...2]
Test socket scaling per volt / TestSktScale/Volt
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
8134
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-